Products > Memory System

Gamma Ray Tool


Product Number:


We're here to help:
Easy ways to get the answers you need.


  • +86-029-88601839
  • +86-029-88601839
  • kingwell@kingwelloilfield.com
  • Follow Us:


Overview


The gamma ray tool (GRT) measures the natural gamma ray generated from the formation that surrounds the wellbore. The sensor comprises a 4" sodium iodide scintillator, a photomultiplier and a 1.6kV high voltage power supply. The models of GRT are compactly designed and offers good sensitivity and high resolution for use in cased-hole production logging operations. The Tool, combined with other tools, may be used for flow tracer work and, with the addition of a gamma source, for gravel pack investigations.

Application

· Lithological identification
· Depth correction
· Identification of radioactive scale
· Tracer monitoring
· Gravel pack monitoring (with an additional gamma source)

Specifications

Model

GRT09

GRT10

OD

35mm (1 3/8”)

43mm (1 11/16”)

Max Working Temperature

175℃ (350℉) 

 175℃ (350℉)

Max Working Pressure

15000psi (103MPa)

15000psi (103MPa)

Shipping Length

787mm (30.98")

774mm (30.47″)

Rig-up Length

692mm (27.24")

679mm (26.73,f)

Weight

3.6kg (7.9lbs)

4.7kg (10.4lbs)

Operating Voltage

14VDC-18VDC (Nor. 17VDC)

14VDC-18VDC (Nor. 17VDC)

Operating Current

35mA±3mA

35mA±3mA

Bus

KWTBus

KWTBus

Measuring Range

0-10000 CPS

0-10000 CPS

Sensor

Sodium iodide (NaI)

Sodium iodide (NaI)

Lower Limits

20keV

20keV

Statistic Variation

≤10%

≤10%